Air treatment, built around your building.

Bring air movement, filtration, temperature and humidity control into a coordinated system. Explore four product families and the sections that shape each arrangement.

Voltvent hygienic air handling unit
PRODUCT RANGE

Choose the application.

Review the construction, model schedule and dimensional information for each series.

SYSTEM CONSTRUCTION

Plan the complete arrangement.

The casing, component sequence and controls work together. Confirm service access, leakage and thermal requirements, component pressure losses and the acoustic target as part of the selected unit specification.

Frame & casing

Sealed modular construction with removable access panels.

Thermal & acoustic insulation

Double-skin panels with insulation selected for the installation.

Air treatment

Filtration, heating, cooling and humidity-control sections.

Recovery & control

Recovery arrangement, fan control and BMS coordination.

CONSTRUCTION OPTIONS

Specify the materials and equipment.

Options vary by series and the selected project arrangement.

Structural frame
Galvanised steel or aluminium profiles
Panel skins
Painted galvanised steel, stainless steel or coated sheet options
Panel thickness
50 / 60 / 70 mm project options; compact series 40–60 mm
Insulation
Rock wool, glass wool or other selected mineral-wool construction
Fan arrangements
Forward-curved, backward-curved, aerofoil, plug or EC configurations
Coil construction
Copper-tube / aluminium-fin or copper-fin arrangements
Humidity control
Steam, water spray, wetted media or atomising sections
Layouts
In-line, stacked or side-by-side air paths
Service & control options
Pressure sensing, inspection windows, lights, door switches, speed control and drain traps
INSIDE THE UNIT

Every section has a purpose.

Select a numbered component in the technical cutaway or choose it from the list.

Open modular air handling unit. Select a numbered component.123456789OPEN ACCESS SIDE

Illustrative modular arrangement. Sections and their sequence depend on the selected application.

COMPONENT 03

Filtration stages

Match particle control to the application.

A first-stage filter protects downstream components. Bag, compact or higher-efficiency stages can be added for the required indoor-air quality. Filter area and the allowance for loading form part of fan selection.

  • Coarse and fine filtration options
  • Accessible withdrawal and sealed filter seating
  • Monitor differential pressure across the filter
ENERGY RECOVERY

Choose the right exchange process.

Temperature, moisture transfer, air-stream separation and available space guide the choice. Recovery performance is established for the actual operating conditions.

01

Plate exchanger

Fixed plates provide separate supply and extract passages. Select crossflow or counterflow geometry, and coordinate bypass and frost protection with the operating sequence.

02

Rotary exchanger

A rotating matrix passes through both air streams. Rotor material and control influence heat and moisture transfer; pressure balance and carry-over control require attention.

03

Run-around coils

A closed liquid circuit links separate supply and extract coils. It suits layouts where the air streams are physically apart; pump energy and frost protection are part of selection.

04

Heat pipe

A sealed refrigerant circuit transfers heat between air-side sections. Orientation, seasonal duty and the available temperature difference determine the useful operating range.

MODULAR ARRANGEMENTS

One system. Different air paths.

Explore typical ways to arrange the functional sections around the installation.

Fan section
01

Fan section

A standalone fan module with service access.

Full air treatment
02

Full air treatment

Filtration, heating, cooling, humidity control and supply fan in one line.

Compact treatment line
03

Compact treatment line

A shorter arrangement with filtration, a coil section and fan.

In-line supply & extract
04

In-line supply & extract

Fan sections at opposite ends with treatment modules between them.

Stacked rotary recovery
05

Stacked rotary recovery

Vertically separated air paths around a rotary heat-recovery section.

Stacked plate recovery
06

Stacked plate recovery

Two air paths with a plate exchanger and a lower treatment line.

Concept layouts, not dimensional or fabrication drawings. The final sequence includes the project’s required access, drainage and controls.

DUCT CONNECTIONS

Match the inlet and outlet route.

Choose top or end connections to coordinate the unit with the duct layout.

U: upper connection. A: end connection.

Outdoor airSupply air

Develop the right unit for your project.

Share the air duty, installation space and application with our sales team.

Privacy Preference

Your privacy, your choice.

We use essential browser storage to remember your preferences. Optional external content, including the office map, only loads with your permission.

You can use the website with essential storage only and change your choice at any time under Privacy preferences in the footer. Read our for details.